Enphase Solar Microinverter Kit

enphase energy

web solarStore

 

 

  • Blue Pacific Solar Products, Inc. BBB Business Review

 

Enphase Energy 45240W Grid-Tied Commercial 3 Phase Solar Kit

enphase package
    permit documents
  • 45.3 kW Grid-Tied Package
  • This fast and easy system employs Enphase micro inverter technology to simplify design and installation. We're always looking for ways to make solar easier and more cost effective for business owners. Independent minded customers are the inspiration behind our solar kits which provide quick and easy installation. Choose the Enphase kit that best fits your available space and budget with the knowledge you can expand your kit at any time down the road. Oh yeah we almost forgot, we supply a custom panel to meter NEC code compliant electrical line drawing for each solar package we sell where we will size the wire and show you how to connect the system.
  • Only: Buy Now
  • Product Details:
  • Specifications:
  • Videos:
  • Documents:

Enphase Energy M215 Commercial Microinverter Grid-Tie System

Kit Description Part Number *STC Array Size Monthly kWh @ 5 Sun Hours Per Day *STC Enphase Inverter Model Type Panel & Inverter Warranty
45,240 Watt, 174 Panel Microinverter Kit EETC-45240 45,240 Watts 6,864 kWh M215-60-2LL-S22-IG Grid Tied Microinverter 25 Years

*STC = "Standard Test Conditions" Definition

Enphase Micro inverters are installed at each solar panel, maximizing energy production and converting the DC power from the panel into standard AC electricity. This offers greater design flexibility and simplified installation, accommodating different roof planes, pitches, or rooftop obstacles. The first to introduce module-level micro inverters, Enphase technology maximizes safety and design flexibility. The M215 Micro inverters are covered by a 25-year limited warranty. Each Enphase Micro inverter is individually connected to one solar panel in your array. This unique configuration means that an individual Maximum Power Point Tracker (MPPT) controls each solar panel. This ensures that the maximum power available from each solar panel is exported to the utility grid regardless of the performance of the other solar panels in the array.

The M215 Micro inverter is connected to the AC branch circuit using the Engage cable system. The Engage Cable is a continuous length of 12AWG cable with per-installed connectors for the Enphase Micro inverters to plug into. The cable is handled like standard outdoor-rated electrical wire, allowing it to be cut, spliced and extended as needed. The Engage system is comprised of ruggedized cabling and accessories that enable fast, easy installations of the Enphase system. Snap-together connectors and waterproof enclosures deliver a streamlined, secure, and standardized approach to array wiring unique to the Enphase System.

Each of the micro inverters that makes up the Enphase 45240W solar kit integrates with Enphase network technology allowing you to monitor each panel performance throughout the day. (Monitor is Optional) Enphase system monitoring capability be accomplished using the optional Envoy monitor by simply plugging into a 120 volt wall outlet. You can also track your solar production by using other different types of monitors, but most customers would opt for the Envoy monitor because you can read individual panel performance rather that the whole systems performance.

diy kits

Enphase Energy, Line Communication Filter 120VAC, for 208/240VAC, with IEMU Communication Hub, ELCF-120-001. The LCF is essentially an outdoor rated box with a built in EMU and filtering for the feed from the PV sub panel.

The Enphase Envoy gateway is the data logger / internet gateway for the micro-inverters in the Enphase micro-inverter system. The micro-inverters communicate performance and production data over power line to the Envoy. We refer to a grouping of one Envoy and the micro-inverters associated with it as a single communications domain. For systems larger than 166 M215-IG micro-inverters more than one Envoy is required. When multiple Envoy gateways are required, a Line Communications Filter is also required, to prevent communications data from one communications domain from cross-talking to another. The line communications filter also contains an Envoy gateway that is connected to the micro-inverter side of the filter network.

These Enphase 45240W Commercial solar kits ship with the new Enphase Integrated Ground (IG) technology. Integrated Ground (IG) technology is a fully-compliant system and equipment grounding incorporated into the microinverter cabling and the microinverter itself, making safety and code compliance easier than ever.

Founded in 1997 with over 20 offices worldwide and 13,700 employees, Trina solar panels are UL certified and was named by EuPD Research as the "Top Brand PV" in Germany in 2013. Photovoltaic projects rely on high quality products that stand the test of time for project inputs ranging from engineering to design to project financing and more. Relative to industry peers, Trina products have a strong 18 year track record of reliability and performance in the field. As a vertically integrated company, Trina tightly controls quality at every step from silicon crystallization to module deployment in the field with 30 in-house quality tests. Trina quality is freight guaranteed by a 25-year industry leading warranty. UL Listed and approved by the California Energy Commisssion.diy kits

What's On the Truck:

  • 174 - 260 Watt Trina Solar Panels, Black Frame, Poly, TSM-260PD05.08
  • 174 - Enphase M215 Microinverters M215-60-2LL-S22-IG
  • 174 - Enphase, Engage AC Trunk Cable, 3-Ph (5-Wire) for M215 and M250, Per Connector Qty, Continuous length in Landscape (67"), ET17-208-BULK
  • 2 - Enphase, Line Communication Filter 120VAC, for 208/240VAC, with Envoy Communications Gateway hub, ELCF-120-001
  • 14 - Enphase, Install Kit for M215 and M250 (4 Terminators, 1 Disconnect Tool, 5 Water tight caps), ET-INSTL
  • 1 Line Drawing; Full Instructive Three-Line Diagram of Entire DC Circuit, as Well as AC Lines to Your Metered Service Entrance.

pvKit Ships in 3 to 5 Business Days After Funds Clear. Trina Solar packages stocked in California, Hawaii & New Jersey. Custom Line Drawing is sent via email in 5 - 7 business days (Line Drawing Lead Time is Subject to Seasonal Increases).

necBest Practice: Center-feed the branch circuit to minimize voltage rise in a fully-populated branch. This practice greatly reduces the voltage rise as compared with an end-fed branch.

Optional Equipment Part # Price  
Enphase, Envoy Communications Gateway Monitor, includesenvoy Wireless USB adapter (WiFi 802.11b/g/n), with Lifetime MyEnlighten System level monitoring, ENV-120-02 M  3600297envoy
Qty
Enphase, Engage Coupler, Watertight Cable Splice for M250 and M250, Qty. 1, ET-SPLK-05ET-SPLK-05  3600204engage
Qty

 

Upgrades Part # Price  
Arrh! Even More Power? Upgrade to the New Enphase M250 Microinverter. The Enphase® M250 Micro inverter delivers increased energy harvest over the traditional Enphase M215. (1 Set Per Panel. enphase M250Example: 10 Panel Kit Upgrade = Add 10 Sets to Upgrade to M250 Each. 20 Panel Kit, Add 20 Sets)  EEM250-UGinverter
Qty

Additional Hardware That May Be Required

aacBlue Pacific Solar has provided all of the main parts you will need for your kit. (See "What's On The Truck") Roof racks and roof rack attachment options or a ground rack system are site specific options that are not included with the base package. The Enphase Envoy monitor is not needed to make your system operate, but is a good idea since it allows you to see the panel level performance. Additionally some additional items sourced from your local hardware store that your may need to purchase are: Conduit, appropriately sized electrical wire from the array, some fasteners, sealant, grounding rod, junction box at the edge of the array where you will make the transition to conduit, an AC combiner box if you have more than one string and a AC disconnect within 10' of the main panel which may be required in some local jurisdictions.

m215

Enphase 45240W Solar Kit Do-It-Yourself Commercial 3 Phase Grid-Tie Package

Enphase 45240W Commercial Solar Kit is relatively simple to layout and install. Blue Pacific Solar has provided all of the main parts you will need for your grid tie package. Here are some additional items that your may need prior to installing your system. Conduit, appropriately sized electrical wire, junction box at the array and with some multiple string systems an AC load center, some fasteners and grounding rod and wire. Building and installing your own home solar system is not only the smart choice for controlling your expenses, it may be on the most satisfying DIY projects you ever have undertaken.

necresidential

NOTE IMPORTANT INSTALLATION: It is the responsibility of the purchaser to ensure that all products are installed and operated in accordance with local and national building codes as specific by the NEC (National Electric Code), UBC (Uniform Building Code) or IBC (International Building Code) and local utility company policy. These codes may vary from city to city and county to county. All Grid-tied solar installations should be permitted and inspected, where required, by the local inspection authority in the same manner as other equivalent electrical systems. It is always a good idea to contract with a local licensed electrician to at least do the final electrical connection of your Enphase 45240W Commercial Solar Kit from the AC disconnect to your home utility breaker box. Some local permitting authorities require that a licensed electrician do all the wiring from the rack to the utility interconnect.

Additional Safety Instructions; Perform all electrical installations in accordance with all applicable local electrical codes and the National Electrical Code (NEC), ANSI/NFPA 70. Be aware that only qualified personnel should install or replace Enphase MicroInverter. Do not attempt to repair the Enphase MicroInverter as it contains no user-serviceable parts. If it fails, please contact Enphase customer service to obtain an RMA (return merchandise authorization) number and start the replacement process. Tampering with or opening the Enphase MicroInverter will void the warranty. Before installing or using the Enphase 45240W Commercial Solar Kit please read all instructions and cautionary markings in the technical description. Connect the Microinverter to the utility grid only after receiving prior approval from the electrical utility company. Be aware that the body of the microinverter is the heat sink. Under normal operating conditions, the temperature is 15°C above ambient, but under extreme conditions the microinverter can reach a temperature of 80°C. To reduce risk of burns, use caution when working with microinverter. Do NOT disconnect the solar panel from the Enphase Energy M215-60-2LL-S22-IG without first removing AC power.

This Enphase 45240W Commercial Solar Kit is an affordable expandable do-it-yourself (DIY) high quality solution for your businesses energy independence.