Pre-Wired Power Center

power system

web solarStore

 

 

  • Blue Pacific Solar Products, Inc. BBB Business Review

 

Outback FlexPower Two FP2-12 Pre-wired Power Center #03304133

Outback FlexPower Two
     
  • FlexPower Two FP2-12
  • off gridFlexPower Two by Outback Power uses all of the essential protective electronic devices and puts them in a compact space. Check out Blue Pacific Solar competitive pricing on all our pre-wired power center products. The FlexPower Two is ideal for applications with minimal power requirements such as off-grid cabins, homes and back-up power systems. Utilizing a compact design and an easy-to-install mounting bracket, the fully pre-wired and tested FlexPower is designed for a quick installation, saving both time and money with just a few household tools. Add up to 2 FlexMax FM80 charge controllers with maximum power point tracking and you have a efficient, safe, multi-stage recharging process that prolongs battery life and assures peak performance from a solar array.
  • Only: Buy Now
  • Product Details:
  • Specifications:
  • Videos:
  • Documents:

Outback FlexPower Two FP2-12 Power Center

Model Part Number Output Watts Input Current Voltage DC/AC Type Inverter
FlexPower Two FP2-12 03304133 7,000 60 Amps 24 / 120 or 240 Off-Grid 2 - VFX3524

 

outback

 

The new Flexpower Two System accommodates all of the essential protective devices in the smallest possible space at the lowest installed cost making it ideal for applications with mid-level power requirements such as homes, workshops and back-up power systems. Utilizing an extremely compact design and an easy-to-install mounting bracket, the fully pre-wired and factory tested Flexpower Two System is designed for a quick installation, saving both time and money.

Flexpower Two includes two inverter/chargers, AC and DC wiring boxes, a MATE2, HUB, and Surge Protector with optional kits for charge controllers (Available as a complete pre-wired system) and DC system monitoring, while maintaining a small system footprint. The Flexpower Two System is also equipped with battery and solar array breakers, an Input-Output-Bypass Assembly, mounting locations for AC GFCI Type B style outlets and additional AC breakers. Flexpower Two components carry all of the necessary ETL Certifications allowing for a code compliant installation that saves both time and money while still looking great.

SURGE PROTECTION: The Flexpower Surge Protector is designed to protect the FlexPower Two’s sensitive components from excessively high voltages (e.g., electrical storms). Thermally-fused metal oxide varistors (MOVs) limit (“clamp”) these voltages and transfer the resulting current to a lower-voltage port. The Flexpower surge protector features ACTIVE and ERROR LEDs for the DC, AC IN, and AC OUT circuits. The Surge Protector is located in the FlexPower Two’s AC wiring compartment.

OutBack Power’s FlexPower Two System is a superior choice when you need a fully integrated, true sinewave, reliable 240V power system.

What's In The Box

  • 1 - FlexPower Two FP2-12 Power Center with 2/Outback VFX3524 Inverters (No Controller) / 03304133
  • 1 OutBack MATE2 Control Module and Displaypower center
  • 1 Outback HUB-10 Communication Manager
  • 1 OutBack RTS - Remote Temp Sensor
  • Prewired AC and DC boxes with 120VAC Bypass and Type B Outlet
  • 2 175A DC breakers
  • X-240 and Surge protector for 120V/240V 60Hz applications

flexpower shipIn most cases, FlexPower systems ship direct from OutBack in about 10 - 15 business days. If you select the controller installed add-on option, allow an additional 5 business days for our factory trained technicians to install and pre-wire the controller option.

 

Electrical Specifications, 120/240 Vac / 60 Hz Models
Product Name FP2-10 FP2-12 FP2-28 FP2-29
Inverter Model 2 VFX3648 2 VFX3524 2 GVFX3524 2 GVFX3648
Grid-Interactive No No Yes Yes
Anti-Islanding Protection N/A N/A UL1741-2005/ IEEE1547 UL1741-2005/ IEEE1547
Output Waveform True Sine Wave True Sine Wave True Sine Wave True Sine Wave
Battery Voltage (Nominal) 48 Vdc 24 Vdc 24 Vdc 48 Vdc
Certifications ETL Listed to UL 1741 ETL Listed to UL 1741 ETL Listed to UL 1741 ETL Listed to UL 1741
Warranty 5-year limited warranty standard / Optional 10-year warranty

generatorFP1-3 / FP1-4 - Because few gas generators produce grid quality AC power, when using OutBack grid-interactive products in conjunction with a generator to recharge batteries, Outback only recommends using Honda EU generators. Flexware relay assembly may be necessary for auto start function of a two wire auto start generator.

 

Optional Charge Controller Part Number   Input Current System Voltage Type Price  
1 - FlexMax 80 Installed BP3510605P dc 80 Amps 12, 24, 36, 48, 60 VDC *MPPT
Qty

generatorUp to 2 FLEXmax FM80 Charge Controllers can be added to the FLEXpower panel. The FM80 add on includes an 80 amp breaker and GFDI in the add-on price.

 

flexpower two

 

trojan battery manual

 

Optional Deep Cycle Battery Choices; Trojan / UPG / Rolls

stand alone kits

Choose the off-grid battery option that best fits your needs. The size of the battery bank you choose depends on the amount of power you require (Watts), the amount of time each day you expect to run your appliances, equipment and lights, and your location or available sunlight. As a rule-of-thumb, when considering batteries off-grid, use 3 days of autonomy (No Sun) as a minimum and 50% depth of discharge for your battery bank.

MFG
Model
Item #   Volt Amp Hour (20Hr Rate) Data WTY 48V Battery Bank Watt Hours Price per Watt Price EA  
Trojan
T-105RE
Flooded Lead Acid
BP4001937 agm battery 6V 225 Ah battery cell 2 YRbattery warranty 8 / T105RE
= 10,800 Wh
$0.11
Qty
Trojan
L16RE-A
Flooded Lead Acid
BP4001967 agm battery 6V 325 Ah battery cell 5 YRtrojan warranty 8 L16RE-A
= 15,600 Wh
$0.15
Qty
UPG
UB-GC2
Sealed AGM
BP9996646 agm battery 6V 200 Ah battery cell 1 YRupg warranty 8 / UB-GC
= 9,600 Wh
$0.21
Qty
Rolls
S6-460
Sealed AGM
BP9946055 surrett S-460AGM 6V 415 Ah agm battery 5 YRserette warranty 8 / S6-460
= 19,200 Wh
$0.21
Qty
Rolls
S-1380
Flooded Lead Acid
BP4002113 surrett 530ah 2V 1050 Ah battery cell 7 YRrolls warranty 24 / S6-460
= 50,400 Wh
$0.16
Qty

 

Battery Cable Pairs (RED/Black) Length Color Part # Price
 2/0 - Battery Cables 12"  1 Red/1 Blackcables BP9850022
Qty
 2/0 - Battery Cables 18"  1 Red/1 Blackcables BP9850012
Qty

 

OUTBACK SEALED AGM BATTERIES

outback batteries

OutBack Power Technologies is a leading designer and manufacturer of reliable power electronics for solar energy applications including solar, wind, micro-hydro, and battery based energy systems. OutBacks' products have been installed in homes, businesses, industrial and government facilities around the world.

 

Battery Model / Type Volts Watt Hours # Batteries Includes Price
Outback EnergyCell 200RE* 12VDC 8,544 Watt Hours 4 Outback 178 aH AGMoutback battery  
Qty
Outback Comprehensive Battery Enclosure (Batteries Sold Separately) - Up to 600AH / 28.8 kW / 28,800 Watts 48VDC Up to 28,000 (28.8 kWh) in one box* battery boxRack Only / BP9890051 Cablesbattery acid
Qty
Outback Battery Enclosure w/ 4 - Outback EnergyCell 200RE Batteries Expandable to 12 Batteries / 28.8kWh Backup Power outback energycell 48VDC Up to 28,000 (28.8 kWh) in one box* 4 Batteries Plus Rack / BP9890050-1outback rack Cablesbattery acid
Qty

NOTE: Outback uses 100 hour discharge rating in their battery advertising AH rating where 20 hour discharge is use in all other battery rating applications listed.

 

Optional Accessories Part # Price  
OutBack Mate Remote Monitor / Controllerbattery charger BP9578062pv charge controller
Qty
OutBack Mate 3 Remote Monitor / Controllerbattery charger BP9578732pv charge controller
Qty
Outback Remote Temperature Sensorpanels BP9500102remote temperature sensor
Qty

 

outback power center

**Freight Shipping is Dock to Dock

outback inverters

In circumstances where we have to ship by freight, free or otherwise, that means dock to commercial dock (not residential) to any of the lower 48 states. If the customer does not specify a local commercial dock that is available, we will ship to the nearest terminal where the shipment will be held for will call pick up by the customer. If you choose to have your order shipped to your residence, most orders require special handling for unloading and the pallet has to be transferred to a truck with a lift gate. In most cases, truck freight companies do NOT require their drivers to unload shipments. An additional "Residential" as well as a "Lift Gate" special handling fee will apply if the driver unloads the merchandise to the curb at your residence. The special handling fee is $89.00 and is available at checkout. If you have selected this add on service, the shipping carrier will call and schedule delivery of your solar kit, (provided the weight and dimensions of the product fits the criteria for lift gate service). You can avoid the residential and lift gate fees by arranging a "Will Call" pickup at the closest freight company terminal. In that case, you will need a pickup truck, a copy of the bill of laden, and a photo ID. When you arrive at the freight company terminal, the freight company will load your order into the bed of the truck with their forklift. The most common pallet size = 65" X 44" (Height depends on Product). Be sure and check for hidden damage.

Outback FlexPower Two Power Center Specifications

FP2-10 7.2 kW FLEXpower TWO, Pre-wired AC and DC boxes with 120VAC Bypass , two 175ADC breakers, two VFX3648 inverter/chargers, MATE2, HUB10, RTS, X-240 and surge protector for 120V/240V 60Hz applications
FP2-12 7 kW FLEXpower TWO, Pre-wired AC and DC boxes with 120VAC Bypass, two 250ADC breakers, two VFX3524 inverter/chargers, MATE2, HUB10, RTS, X-240 and surge protector for 120V/240V 60Hz applications
FP2-22 6 kW FLEXpower TWO, Pre-wired AC and DC boxes with 230VAC Bypass, two 175ADC breakers, two VFX3048E inverter/chargers, MATE2, HUB10 and RTS for 230V 50Hz applications
FP2-24 6 kW FLEXpower TWO, Pre-wired AC and DC boxes with 230VAC Bypass, two 250ADC breakers, two VFX3024E inverter/chargers, MATE2, HUB10 and RTS for 230V 50Hz applications
FP2-28 7 kW FLEXpower TWO, Pre-wired AC and DC boxes with 120VAC Bypass, two 250ADC breakers, two GVFX3524 inverter/chargers, MATE2, HUB10, RTS, and surge protector for 120V/240V 60Hz applications
FP2-29 7.2 kW FLEXpower TWO, Pre-wired AC and DC boxes with 120VAC Bypass, two 175ADC breakers, two GVFX3648 inverter/chargers, MATE2, HUB10, RTS, and surge protector for 120V/240V 60Hz applications
FP2-30 6 kW FLEXpower TWO, Pre-wired AC and DC boxes with 120VAC Bypass, two 175ADC breakers, two GTFX3048-HI inverter/chargers, MATE2, HUB10, RTS, and surge protector for 120V/240V 60Hz applications
FP2-31 6 kW FLEXpower TWO, Pre-wired AC and DC boxes with 120VAC Bypass, two 175ADC breakers, two FX3048T inverter/chargers, MATE2, HUB10, RTS, X-240 and surge protector for 120V/240V 60Hz applications
FP2-32 5 kW FLEXpower TWO, Pre-wired AC and DC boxes with 120VAC Bypass, two 250ADC breakers, two FX2524T inverter/chargers, MATE2, HUB10, RTS, X-240 and surge protector for 120V/240V 60Hz applications
FP2-33 5 kW FLEXpower TWO, Pre-wired AC and DC boxes with 120VAC Bypass, two 250ADC breakers, two GTFX2524-HI inverter/chargers, MATE2, HUB10, RTS, and surge protector for 120V/240V 60Hz applications
Weight Unit                232 lbs (105 kgs)
Shipping        282 lbs (127 kgs)
(H x W x L)      Unit                20.25 x 46.5 x 13 (51.4 x 118.1 x 33 cm)
Shipping        21.5 x 47.5 x 20.5” (54.6 x 120.7 x 52.1 cm)

 

Outback Flexmax 80 / 60 Charge Controller Specifications

FLEXmax 80 Specifications FLEXmax 60 Specifications
Nominal Battery Voltages 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up)
Maximum Output Current 80 amps @ 104° F (40°C) with adjustable current limit 60 amps @ 104° F (40°C) with adjustable current limit
Maximum Solar Array STC Nameplate 12 VDC systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts / 60 VDC systems 6250 Watts 12 VDC systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts
NEC Recommended Solar Array STC Nameplate 12 VDC systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts / 60 VDC Systems 5000 Watts 12 VDC systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts / 60 VDC Systems 3750 Watts
PV Open Circuit Voltage (VOC) 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum
Standby Power Consumption Less than 1 Watt typical Less than 1 Watt typical
Power Conversion Efficiency 97.5% @ 80 Amps in a 48 VDC System - Typical 98.1% @ 60 Amps in at 48 VDC System voltage - Typical
Charging Regulation Five Stages: Bulk, Absorption, Float, Silent and Equalization Five Stages: Bulk, Absorption, Float, Silent and Equalization
Voltage Regulation Set points 10 to 80 VDC user adjustable with password protection 10 to 80 VDC user adjustable with password protection
Equalization Charging Programmable Voltage Set point and Duration - Automatic Termination when completed Programmable Voltage Set point and Duration - Automatic Termination when completed
Battery Temperature Compensation Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell
Voltage Step-Down Capability Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input
Programmable Auxiliary Control Output 12 VDC output signal which can be programmed for different control applications
(Maximum of 0.2 amps DC)
12 VDC output signal which can be programmed for different control applications
(Maximum of 0.2 amps DC)
Status Display 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total
Remote Display and Controller Optional Mate or Mate2 with RS232 Serial Communications Port Optional Mate or Mate2 with RS232 Serial Communications Port
Network Cabling Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)
Data Logging Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production
Hydro Turbine Applications Consult factory for approved Turbines Consult factory for approved Turbines
Positive Ground Applications Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications)
Operating Temperature Range Minimum -40° to maximum 60° C
(Power capacity of the controller is automatically derated when operated above 40° C)
Minimum -40° to maximum 60° C
(Power capacity of the controller is automatically derated when operated above 40° C)
Environmental Rating Indoor Type 1 Indoor Type 1
Conduit Knockouts One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom
Warranty Standard 5 year / Available 10 Year Standard 5 year / Available 10 Year
Weight - Unit 12.20 lbs (5.56 kg) 11.65 lbs (5.3 kg)
         - Shipping 15.75 lbs (7.10 kg) 14.55 lbs (6.4 kg)
Dimensions - Unit 16.25" x 5.75" x 4" (41.3 x 14 x 10 cm) -
(H x W x D)
13.5 x 5.75 x 4" (40 x 14 x 10 cm)
         - Shipping 21" x 10.5" x 9.75" (53 x 27 x 25 cm) 18 x 11 x 8" (46 x 30 x 20 cm)
Options Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2 Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2
Menu Languages English & Spanish English & Spanish
blackout power

Outback Flexpower FP2-12 Pre-wired 120/240V AC Pre-wired Power Center

Outback FlexPower Two Power Centers are solid-state electronic devices that, when sized properly, can be used in nearly every solar and wind energy system that uses batteries. The Power Centers Blue Pacific Solar sells employ the latest in power electronics to regulate the battery charge by controlling the charging voltage and current from a solar panel array. Power Centers regulate the charge of the battery, but also prevent the battery from being over discharged which can damage the battery bank.

Off-grid or grid tied with battery backup, here is how the FlexPower Power System basically works. For a grid tied battery backup, grid power comes into the Outback FlexPower power center. If the backup batteries are fully charged, the power is then passed to the critical load or backup load subpanel inside the home. The FlexPower power system is monitoring the sine wave of the grid, amps and volts. When the FlexPower system detects changes outside the default parameters, it immediately begins to draw power from the backup battery system and pushes it to the critical load subpanel.

flexpower power center IMPORTANT SAFETY INSTRUCTIONS: FlexPower Two Power Center. (OK, here is the scary legal disclaimer.) It is the responsibility of the purchaser to ensure that all products are installed and operated in accordance with local and national building codes as specific by the NEC (National Electric Code), UBC (Uniform Building Code) or IBC (International Building Code) and local utility company policy. This product is designed for indoor or protected compartment installations. DO NOT expose the Outback FlexPower Two to rain, snow, moisture or liquids of any type. Use insulated tools to reduce the chance of electrical shock or accidental short circuits. Remove all jewelry such as rings, watches, bracelets, etc. when installing the FlexPower Two Power Center or any other electronic gear. Always disconnect the batteries or energy source prior to installation or performing maintenance on the FlexPower Two Power Center inverter. Live power may be present at more than one point since an inverter utilizes both batteries and AC electricity. Turning off the FlexPower Two Power Center may not reduce that risk. Always verify proper wiring prior to starting the inverter. Do not operate the FlexPower Two Power Center if it has been damaged. Always read and follow the manufactures installation and operating instructions for the Outback Flexpower FP2-12 Pre-wired 120/240V AC Power Center prior to installation and operation.