  • Magnum MS4448PAE-4 Power Center, pre-wired and shipped ready to hang on your wall. This is one tough off and on grid Quad inverter with breakers and all the essential protective electronic devices with a very small footprint. Serious power for midsize cabins or homes. You can combine this system with a grid interactive connection after separating out your critical loads and you have an on grid backup inverter that will keep your batteries up-to-speed allowing you to keep the lights on when the utility goes down.
    Made USA
    Add optional charge controllers at a later date along with some solar panels and run your home off the grid indefinitely if you manage your power. Be ready for anything that comes your way. Off-grid living, utility blackouts, snow storms and hurricanes The Magnum will handle it all. (Psst... its also way cool that it's made in America!)
  • Only: Buy Now
  • Product Details:
  • Specifications:
  • Videos:
  • Documents:

Magnum MS4448PAE-4 Quad Power Center

Model Part Number Output Watts Breakers Voltage DC/AC Type Shipping Weight
Magnum MS4448PAE-4 Quad Inverter Power Center BP2800455 17,600 30A Dual or 60A Single AC Input/Output Breakers 48VDC / 120 / 240VAC Off-Grid / On Grid 551 lbs

 

magnum

All Magnum MS4448PAE-4 power systems supply split-phase 120 / 240 AC volt power for direct connection to your home 120 / 240 volt breaker panel or can be used off the grid. Multiple Magnum MS4448PAE series inverters are connect in parallel through the Magnum router interface. One Magnum MS4448PAE inverter is designated as a master and is active continuously, while the remaining slave inverters are maintained in "idle mode" for low power consumption. As more energy is required, the slave inverters "wake up" progressively to meet the demand. This power center is perfect for on grid and off-grid applications because it greatly improves overall efficiency and keeps power consumption to a minimum.

Pre-wired and pre-tested for 120 / 240 VAC / 60Hz applications, Magnum MS4448PAE-4 power systems have been specifically designed to combine all of the major components required for a high power home or off grid system. Magnum MS4448PAE power systems have all of the circuit breakers and controls right up front for convenience and easy code-compliance. Magnum MS4448PAE power systems includes a main DC disconnect circuit breaker to protect each inverter, inverter bypass breakers, and inverter input breakers as standard equipment. In addition, Blue Pacific Solar includes an optional DC input and output circuit breakers with each installed MidNite Solar or OutBack charge controller.

Your Magnum MS4448PAE power system comes standard with the ME-RTR router controller (See Document Tab). The ME-RTR router is needed to interface with 2 or more Magnum MS4448PAE inverters, and also gives you advanced control and monitoring of the power system. The controller has user friendly buttons and knob that gives you an easy to read menu system. You do not need an additional remote control unit to operate the power system, but if you want remote monitoring and control capability, an optional remote control can be located up to 150' away from the power center (50' cable included) to provide Magnum MS4448PAE power center monitoring and limited control at a more convenient location. The Magnum ME-BMK battery monitor kit is included to supply easy to access information about your battery state of charge, voltage, real-time amps, etc. This is a quality built and certified power center that because it is installed in a Magnum panel extends the inverter warranty to 5 years.

magnum power center

What's On The Truck

  • Magnum Energy MS448PAE-4 (Quad); Power center comes pre-wired and tested by experienced factory trained technicians.
  • 1 - Magnum Router - ME-RTR
  • 1 - Magnum Energy BMK Battery Monitor-No Shunt
  • Magnum MMP System Monitor Gives Instant Status and Battery State of Charge
  • Attractive White Powder Coated Box with Easy to See Front Facing Controls
  • AC and DC Input Breakers
  • Additional Breaker Space for DIN Rail or Surface Mount Breakers for Optional Equipment
  • Lightning Arrestors
  • Inverter Bypass Switch Allows Choice of Generator / Grid or Inverter Output
  • Easy to Connect Color Coded Buss Bars for AC and DC Connections
  • Single System Grounding Point
  • Clearly Labeled Connection Points for AC and DC Input and Output
  • ETL and C-ETL Listed Magnum Energy Power

 

Inverter Options Description Part # Price  
ME-AGS-N Automatic Generator Start WORKS WITH;
ME Series, MM Series, MMS Series, MS Series, MS-PAE Series, RD Seriesmppt
BP2911442solar charger
Qty

 

Charge Controller Mounted on The Power Center Part Number   Input Current System Voltage Type Price  
MidNite Solar Classic 150
Mounted on Power Center
BP3900141P dc 205 VDC 12 - 93 VDC *MPPT
Qty
MidNite Solar Classic 250
Mounted on Power Center
BP3920051 dc 315 VDC 12 - 93 VDC *MPPT
Qty
OutBack FlexMax 60
Mounted on Power Center
BP3552283P dc 60 Amps 12, 24, 36, 48, 60 VDC *MPPT
Qty
OutBack FlexMax 80
Mounted on Power Center
BP3510605P dc 80 Amps 12, 24, 36, 48, 60 VDC *MPPT
Qty

 

trojan battery manual

Trojan / UPG / Rolls Deep Cycle Batteries

batteries

Choose the off-grid battery option that best fits your needs. The size of the battery bank you choose depends on the amount of power you require (Watts), the amount of time each day you expect to run your appliances, equipment and lights, and your location or available sunlight (If you are adding solar or wind power). As a rule-of-thumb, when considering batteries off-grid, use 3 days of autonomy (No Sun) as a minimum and 50% depth of discharge for your battery bank.

MFG
Model
Item #   Volt Amp Hour (20Hr Rate) Data WTY 48V Battery Bank Watt Hours Price per Watt Price EA  
Trojan
T-105RE
Flooded Lead Acid
BP4001937 agm battery 6V 225 Ah battery cell 2 YRupg warranty 8 / T105RE
= 10,800 Wh
$0.11
Qty
Trojan
L16RE-A
Flooded Lead Acid
BP4001967 agm battery 6V 325 Ah battery cell 5 YRupg warranty 8 L16RE-A
= 15,600 Wh
$0.15
Qty
UPG
UB-GC2
Sealed AGM
BP9996646 agm battery 6V 200 Ah battery cell 1 YRupg warranty 8 / UB-GC
= 9,600 Wh
$0.21
Qty
Rolls
S6-460
Sealed AGM
BP9946055 surrett S-460AGM 6V 415 Ah agm battery 5 YRserette warranty 8 / S6-460
= 19,200 Wh
$0.21
Qty
Rolls
S-1380
Flooded Lead Acid
BP4002113 surrett 530ah 2V 1050 Ah battery cell 7 YRrolls warranty 24 / S6-460
= 50,400 Wh
$0.16
Qty

 

2/0 Battery Cable Pairs (RED/Black) Length Color Part # Price  
 2/0 - Battery Cables 12"  1 Red/1 Blackagm gel batteries BP9850022
Qty
 2/0 - Battery Cables 18"  1 Red/1 Blackbattery cables BP9850012
Qty
 2/0 - Battery Cables 24"  1 Red/1 Blackagm gel batteries BP9960208
Qty
 4/0 - Battery Cables 48"  1 Red/1 Blackagm gel batteries BP9922480
Qty
 4/0 - Battery Cables 60"  1 Red/1 Blackagm gel batteries BP9906000
Qty
 4/0 - Battery Cables 120"  1 Red/1 Blackagm gel batteries BP9901208
Qty

 

solar power centers

 

magnum energy

**Freight Shipping is Dock to Dock

magnum inverters

In circumstances where we have to ship by freight, free or otherwise, that means dock to commercial dock (not residential) to any of the lower 48 states. If the customer does not specify a local commercial dock that is available, we will ship to the nearest terminal where the shipment will be held for will call pick up by the customer. If you choose to have your order shipped to your residence, most orders require special handling for unloading and the pallet has to be transferred to a truck with a lift gate. In most cases, truck freight companies do NOT require their drivers to unload shipments. An additional "Residential" as well as a "Lift Gate" special handling fee will apply if the driver unloads the merchandise to the curb at your residence. The special handling fee is $89.00 and is available at checkout. If you have selected this add on service, the shipping carrier will call and schedule delivery of your solar kit, (provided the weight and dimensions of the product fits the criteria for lift gate service). You can avoid the residential and lift gate fees by arranging a "Will Call" pickup at the closest freight company terminal. In that case, you will need a pickup truck, a copy of the bill of laden, and a photo ID. When you arrive at the freight company terminal, the freight company will load your order into the bed of the truck with their forklift. The most common pallet size = 65" X 44" (Height depends on Product). Be sure and check for hidden damage.

Inverter

Magnum Energy MS4448PAE Pure Sine Wave

Input battery voltage range 36.0 - 68.0 VDC
Nominal AC output voltage 120 / 240 VAC split phase (± 5%)
Output frequency and accuracy 60 Hz ± 0.1 Hz
1 msec surge current (amps AC) Line-Neutral: 120, Line-Line: 70
5 sec surge power (real watts) 8500
30 sec surge power (real watts) 6000
5 min surge power (real watts) 5400
30 min surge power (real watts) 4800
Continuous power output at 25° C 4400 VA (L-L)
Maximum continuous input current 144 A
Inverter efficiency (peak) 94%
No load (120 VAC output, typical) 25 watts
Waveform Pure Sine Wave
Charger Continuous output at 25° C 60 ADC
Input current at rated output (AC amps) 17.5 AAC per leg at 120/240 VAC split phase
Power factor Greater Than 0.95

Operating Temperatures

Operating temperature -20° C to +60° C (-4° F to 140° F)
Non-operating temperature -40° C to +70° C (-40° F to 158° F)
 

Monitor

Magnum Energy ME-ARC Remote Control

LED Display Display shows inverter and battery status
16 x 2 line (32 characters total), alphanumeric display used for programming the Magnum inverter operation and or fault messages.
Pushbutton Controls Two ON/OFF Pushbuttons allow the inverter to be quickly enabled or disabled.
Menu allow the inverter to be configured to site specific preferences. Menus give simple access to monitoring and troubleshooting backup power system.
Rotary Knob controlls the selection and can scroll through and select various menu items and settings. By pushing you can “SELECT” a menu item or “Save” a setting once it is displayed on the LCD screen.
 

 

MidNite Solar Classic Charge Controllers
Classic 150 Classic 200 Classic 250 Classic 250KS
Operating Volts In 150VDC 200VDC 250VDC 250VDC
*Max Hyper VOC 150+ battery 200+ battery 250+ battery 250+ battery
Nominal Battery Volts 12-72 12-72 12-72 12-120
**Absolute Current Output at 25° C

93a@12v battery

94a @ 24v battery

83a @ 48v battery

74a @ 12v battery

70a @ 24v battery

65a @ 48v battery

60a @ 12v battery

62a @ 24v battery

55a @ 48v battery

40a @ 120v battery
De-Rate Current @ 40° C 80 amperes 60 amperes 52 amperes 33 amperes
Environment -40° C to 40° C
Classic Dimensions 14.87” x 5.95” x 4.00” (378 mm x 151 mm x 102 mm)
Boxed Dimensions 19.00” x 8.50” x 5.70” (378 mm x 151 mm x 102 mm)
Shipping Weight 11.5 lb (4.9 kg)

NOTE: Current output ratings were measured with 75% of the PV array’s VOC (Open Circuit Voltage)
*NOTE: Calculated by adding battery voltage to the maximum input operating voltage (48V battery max)
**NOTE: Measurement Accuracies: +-0.12v, offset calibration adjustment may be necessary

Outback Flexmax 80 / 60 Charge Controller Specifications

FLEXmax 80 Specifications FLEXmax 60 Specifications
Nominal Battery Voltages 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up)
Maximum Output Current 80 amps @ 104° F (40°C) with adjustable current limit 60 amps @ 104° F (40°C) with adjustable current limit
Maximum Solar Array STC Nameplate 12 VDC systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts / 60 VDC systems 6250 Watts 12 VDC systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts
NEC Recommended Solar Array STC Nameplate 12 VDC systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts / 60 VDC Systems 5000 Watts 12 VDC systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts / 60 VDC Systems 3750 Watts
PV Open Circuit Voltage (VOC) 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum
Standby Power Consumption Less than 1 Watt typical Less than 1 Watt typical
Power Conversion Efficiency 97.5% @ 80 Amps in a 48 VDC System - Typical 98.1% @ 60 Amps in at 48 VDC System voltage - Typical
Charging Regulation Five Stages: Bulk, Absorption, Float, Silent and Equalization Five Stages: Bulk, Absorption, Float, Silent and Equalization
Voltage Regulation Set points 10 to 80 VDC user adjustable with password protection 10 to 80 VDC user adjustable with password protection
Equalization Charging Programmable Voltage Set point and Duration - Automatic Termination when completed Programmable Voltage Set point and Duration - Automatic Termination when completed
Battery Temperature Compensation Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell
Voltage Step-Down Capability Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input
Programmable Auxiliary Control Output 12 VDC output signal which can be programmed for different control applications
(Maximum of 0.2 amps DC)
12 VDC output signal which can be programmed for different control applications
(Maximum of 0.2 amps DC)
Status Display 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total
Remote Display and Controller Optional Mate or Mate2 with RS232 Serial Communications Port Optional Mate or Mate2 with RS232 Serial Communications Port
Network Cabling Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)
Data Logging Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production
Hydro Turbine Applications Consult factory for approved Turbines Consult factory for approved Turbines
Positive Ground Applications Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications)
Operating Temperature Range Minimum -40° to maximum 60° C
(Power capacity of the controller is automatically derated when operated above 40° C)
Minimum -40° to maximum 60° C
(Power capacity of the controller is automatically derated when operated above 40° C)
Environmental Rating Indoor Type 1 Indoor Type 1
Conduit Knockouts One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom
Warranty Standard 5 year / Available 10 Year Standard 5 year / Available 10 Year
Weight - Unit 12.20 lbs (5.56 kg) 11.65 lbs (5.3 kg)
         - Shipping 15.75 lbs (7.10 kg) 14.55 lbs (6.4 kg)
Dimensions - Unit 16.25" x 5.75" x 4" (41.3 x 14 x 10 cm) -
(H x W x D)
13.5 x 5.75 x 4" (40 x 14 x 10 cm)
         - Shipping 21" x 10.5" x 9.75" (53 x 27 x 25 cm) 18 x 11 x 8" (46 x 30 x 20 cm)
Options Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2 Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2
Menu Languages English & Spanish English & Spanish
blackout power

Magnum MS4448PAE-4 Power Center Documents & Manuals

 
magnum inverter Inverter
 
charge controller Standard ME-RTR Controller (Included)
 
charge controller Optional (Not Included) Remote Controller

Magnum MS4448PAE-4 Pre-wired Power Center 120 / 240 Volts AC Pure Sine Wave Energy

Magnum MS4448PAE-4 Power Center is solid-state electronic device that, when sized properly, can be used in nearly every solar and wind energy system that uses batteries. The Power Centers Blue Pacific Solar sells employ the latest in power electronics to regulate the battery charge by controlling the charging voltage and current from a solar panel array. Power Centers regulate the charge of the battery, but also prevent the battery from being over discharged which can damage the battery bank.

Off-grid or grid tied with battery backup, here is how the Magnum MS4448PAE-4 Power Center basically works. For a grid tied battery backup, grid power comes into the Magnum MS4448PAE-4 Power Center. If the backup batteries are fully charged, the power is then passed to the critical load or backup load subpanel inside the home. The Outback FlexPower power system is monitoring the sine wave of the grid, amps and volts. When the Magnum MS4448PAE-4 Power Center detects changes outside the default parameters, it immediately begins to draw power from the backup battery system and pushes it to the critical load subpanel.

If you have solar panel system connected to the Magnum MS4448PAE-4 Power Center, the power center will use the electricity produced by your solar panels to charge the batteries making Magnum MS4448PAE-4 Power Center a great choice for home backup and off-grid systems.

Magnum MS4448PAE-4 Power Center Power Center uses multiple stages of control to regulate different voltage and current levels. The voltage and current of a battery varies over the different stages of battery charge. Though the amount can vary, the bulk charge usually is approximately 80%, the absorption charge is 10% with the float charge representing the balance of the battery charging process.

The bulk charging stage of the Magnum MS4448PAE-4 Power Center Power Center process is the first stage to used to bring the battery depth of discharge (DOD) back to 100%. The bulk charge stage happens first in in the morning after the batteries DOD has drained down since sunset the previous day. The bulk charging stage pushes as many amps into the battery bank as possible from the solar panels and gets the voltage up in the process. The effect of a Power Center is not unlike trying to fill a glass of water from a faucet. You first turn the faucet on full while the glass if filling, then slowly taper off the pressure until the glass is full. When the battery bank reaches a predetermined level known as the bulk voltage set-point, the charge is then substantially slowed. Because the bulk voltage set point is determined by the type of battery you are using, many Power Centers have to be pre-set to the type of battery which will dictate the rate of charge.

The second state of charge the Magnum MS4448PAE-4 Power Center employs is the absorption stage. After a battery system has been brought up to the bulk voltage set point, the Power Center slows down the charge rate because the battery bank cannot accept the same rapid charging pace without overheating and damaging the battery bank. At the absorption stage a battery bank is only about 80% full. The absorption charge is the function level in the process that tops off the battery bank. During the absorption stage, the Power Center holds the battery volts constant and reduces the amount of current sent into the battery. When the absorption stage is complete, the battery bank is fully charges.

The final step the Magnum MS4448PAE-4 Power Center performs is the float charge. Typically a charge controller enters into a float charge state when the other charge levels of the battery bank has been achieved. When the number of peak sun hours is limited, a solar Power Center may not be able to get the battery bank back to the float stage before the next cycle begins.

Each Magnum MS4448PAE-4 Power Center comes pre-wired with inverter, optional charge controller all mounted on a rack ready to power up. You simply have to finish connecting into your battery bank and wire to your breaker box or subpanel. Simple, easy, fast.

magnum power center IMPORTANT SAFETY INSTRUCTIONS: Magnum MS4448PAE-4 Power Center. (OK, here is the scary legal disclaimer.) It is the responsibility of the purchaser to ensure that all products are installed and operated in accordance with local and national building codes as specific by the NEC (National Electric Code), UBC (Uniform Building Code) or IBC (International Building Code) and local utility company policy. This product is designed for indoor or protected compartment installations. DO NOT expose the Magnum Panel System to rain, snow, moisture or liquids of any type. Use insulated tools to reduce the chance of electrical shock or accidental short circuits. Remove all jewelry such as rings, watches, bracelets, etc when installing the Magnum Panel System Power Center or any other electronic gear. Always disconnect the batteries or energy source prior to installation or performing maintenance on the Magnum Panel System Power Center inverter. Live power may be present at more than one point since an inverter utilizes both batteries and AC electricity. Turning off the Magnum Panel System Power Center may not reduce that risk. Always verify proper wiring prior to starting the inverter. Do not operate the Magnum MS4448PAE-4 Power Center Power Center if it has been damaged. Always read and follow the manufactures installation and operating instructions for the Magnum Panel System Power Center prior to installation and operation.