  • Magnum MMS1012 E-Panel System is shipped pre-wired and ready to hang and connect with all the essential protective electronic devices with a very small footprint. Blue Pacific Solar is able to offer very competitive pricing on all our pre-wired power center products.  Magnum / MidNite Solar E-Panel power systems are ideal for applications with minimal to medium power requirements such as off-grid cabins and homes needing back-up power systems. Utilizing a compact design and an easy-to-install mounting bracket,
    Made USA
    the fully pre-wired and tested system is designed for a quick installation, saving both time and money with just a few household tools. (Psst... its also very cool that its all made in America.)
  • Only: Buy Now
  • Product Details:
  • Specifications:
  • Videos:
  • Documents:

Magnum MMS1012 E-Panel System Power Center

Model Part Number Output Watts Input Current Voltage DC/AC Type Shipping Weight
Magnum MMS1012 E-Panel Power System BP271012 1,000 20 Amps 12VDC / 120 VAC Off-Grid / On Grid 109 lbs.

 

magnum

Magnum MMS1012 E-Panel system and pure sine wave power center. The insides of the MMS1012 E-Panel system is professionally wired and shipped ready to install. Designed for the MMS1012 E-Panel system inverters. Gray steel chassis with 125-amp inverter breaker. The MidNite Solar E-Panel is the quickest way to install Magnum MM series inverters. MMS1012 E-Panel system comes standard with the basic over-current protection and disconnects required to install your solar energy system. Listed to UL and CSA standards. The MMS1012 E-Panel system comes with inverter breaker, pre-wired AC input and bypass, 500amp 50mV shunt, AC terminal blocks, 100 amp DC positive and DC negative bus bars, solar input bus bar, din rails, 3 panel mount breaker knockouts, Ground bus bar, DC wiring cover, top shield, remote display mounting bracket, wall mounting brackets and charge controller bracket. Charge controller mounted on the power center is optional. We recommend the MidNite Solar Classic 150 charge controller.

power center

What's On The Truck

  • 1 - Magnum MMS1012 E-Panel System Power Center Fully Assembled (No Controller) BP271012
  • 1 Magnum Energy MMS1012, 1000 Watt Sine wave Inverter
  • 1 Magnum Energy MREMOTE Small Remote
  • 1 Magnum ME-BMK Battery Monitor Kit
  • System Monitor Gives Instant Status and "Percent of Full" Battery Information
  • ETL and C-ETL Listed MidNite Solar E-Panel
  • Lightning Arrestors
  • Pre-wired AC bypass and AC input, 125 Amp Inverter Battery Breaker
  • All steel construction
  • Easy to Connect Color Coded Buss Bars for AC and DC Connections
  • Multiple Available Knockouts for Conduit Attachments
  • Single System Grounding Point
  • Clearly Labeled Connection Points for AC and DC Input and Output
  • Fully Assembled and Tested by Experienced Factory Trained Technicians
  • All Required Internal Cables and Connectors

 

Charge Controller Mounted on The Power Center Part Number   Input Current System Voltage Type Price  
MidNite Solar Classic 150
Mounted on Power Center
BP3900141P dc 205 VDC 12 - 93 VDC *MPPT
Qty
MidNite Solar Classic 250
Mounted on Power Center
BP3920051 dc 315 VDC 12 - 93 VDC *MPPT
Qty
OutBack FlexMax 60
Mounted on Power Center
BP3552283P dc 60 Amps 12, 24, 36, 48, 60 VDC *MPPT
Qty
OutBack FlexMax 80
Mounted on Power Center
BP3510605P dc 80 Amps 12, 24, 36, 48, 60 VDC *MPPT
Qty

 

trojan battery manual

Trojan / UPG / Rolls Deep Cycle Batteries

batteries

Choose the off-grid battery option that best fits your needs. The size of the battery bank you choose depends on the amount of power you require (Watts), the amount of time each day you expect to run your appliances, equipment and lights, and your location or available sunlight (If you are adding solar or wind power). As a rule-of-thumb, when considering batteries off-grid, use 3 days of autonomy (No Sun) as a minimum and 50% depth of discharge for your battery bank.

MFG
Model
Item #   Volt Amp Hour (20Hr Rate) Data WTY 12V Battery Bank Watt Hours Price per Watt Price EA  
Trojan
T-105RE
Flooded Lead Acid
BP4001937 agm battery 6V 225 Ah battery cell 2 YRupg warranty 2 / T105RE = 2,700 Wh $0.11
Qty
Trojan
L16RE-A
Flooded Lead Acid
BP4001967 agm battery 6V 325 Ah battery cell 5 YRupg warranty 2 L16RE-A = 3,900 Wh $0.15
Qty
UPG
UB-GC2
Sealed AGM
BP9996646 agm battery 6V 200 Ah battery cell 1 YRupg warranty 2 / UB-GC = 2,400 Wh $0.21
Qty
Rolls
S6-460
Sealed AGM
BP9946055 surrett S-460AGM 6V 415 Ah agm battery 5 YRserette warranty 2 / S6-460 = 4,980 Wh $0.21
Qty
Rolls
S-1380
Flooded Lead Acid
BP4002113 surrett 530ah 2V 1050 Ah battery cell 7 YRrolls warranty 2 / S6-460 = 12,600 Wh $0.16
Qty

 

magnum midnite

 

magnum energy

**Freight Shipping is Dock to Dock

magnum inverters

In circumstances where we have to ship by freight, free or otherwise, that means dock to commercial dock (not residential) to any of the lower 48 states. If the customer does not specify a local commercial dock that is available, we will ship to the nearest terminal where the shipment will be held for will call pick up by the customer. If you choose to have your order shipped to your residence, most orders require special handling for unloading and the pallet has to be transferred to a truck with a lift gate. In most cases, truck freight companies do NOT require their drivers to unload shipments. An additional "Residential" as well as a "Lift Gate" special handling fee will apply if the driver unloads the merchandise to the curb at your residence. The special handling fee is $89.00 and is available at checkout. If you have selected this add on service, the shipping carrier will call and schedule delivery of your solar kit, (provided the weight and dimensions of the product fits the criteria for lift gate service). You can avoid the residential and lift gate fees by arranging a "Will Call" pickup at the closest freight company terminal. In that case, you will need a pickup truck, a copy of the bill of laden, and a photo ID. When you arrive at the freight company terminal, the freight company will load your order into the bed of the truck with their forklift. The most common pallet size = 65" X 44" (Height depends on Product). Be sure and check for hidden damage.

Inverter Specifications

Magnum Energy MMS1012 Inverter

Input battery voltage range 9 - 17 VDC
Nominal AC output voltage 120 Volts AC
Output frequency and accuracy 60 Hz ± 0.1 %
1 msec surge current (amps AC) 50
5 sec surge power (real watts) 3300
30 sec surge power (real watts) 3100
5 min surge power (real watts) 2800
30 min surge power (real watts) 2200
Continuous power output at 25° C 2000 VA
Maximum continuous input current 266 ADC
Inverter efficiency (peak) 89%
No load (120 VAC output, typical) 25 watts
Waveform Pure Sine Wave
Charger Continuous output at 25° C 100 ADC
Input current at rated output (AC amps) 15
Power factor > 0.95

General Features and Capabilities

Transfer relay capability MS2000: 30 A single input MS2012, MS2812, MS4024: 2 legs at 30 A for 120 V/30 A or 240 V/60 A service
Five stage charging capability Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™
Remote available (optional) Yes, MM-RC or ME-RC
Overcurrent protection Yes, with two overlapping circuits
Dual AC branch rated output breakers Optional on the MS2000 and MS2012 - AC breakers in 15 or 20 amp ratings
Listings ETL Listed to UL/cUL 458, UL 1741, CSA C22.2 #107.1-01, meets KKK-A-1822E standard
Warranty Three years

Environmental Specifications

Operating temperature -20° C to +60° C (-4° F to 140° F)
Non-operating temperature -40° C to +70° C (-40° F to 158° F)
 

Physical Specifications

Dimensions (L x W x H) 13.75” x 12.65” x 8.0”
Mounting Shelf (top or bottom up) or bulkhead (vents up)
Weight 42 Lbs.
Shipping Weight 48 Lbs.
Max operating altitude 15,000’
 

 

Outback FlexMax 80 / 60 Charge Controller Specifications

FlexMax 80 Specifications FlexMax 60 Specifications
Nominal Battery Voltages 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up)
Maximum Output Current 80 amps @ 104° F (40°C) with adjustable current limit 60 amps @ 104° F (40°C) with adjustable current limit
Maximum Solar Array STC Nameplate 12 VDC systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts / 60 VDC systems 6250 Watts 12 VDC systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts
NEC Recommended Solar Array STC Nameplate 12 VDC systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts / 60 VDC Systems 5000 Watts 12 VDC systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts / 60 VDC Systems 3750 Watts
PV Open Circuit Voltage (VOC) 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum
Standby Power Consumption Less than 1 Watt typical Less than 1 Watt typical
Power Conversion Efficiency 97.5% @ 80 Amps in a 48 VDC System - Typical 98.1% @ 60 Amps in at 48 VDC System voltage - Typical
Charging Regulation Five Stages: Bulk, Absorption, Float, Silent and Equalization Five Stages: Bulk, Absorption, Float, Silent and Equalization
Voltage Regulation Set points 10 to 80 VDC user adjustable with password protection 10 to 80 VDC user adjustable with password protection
Equalization Charging Programmable Voltage Set point and Duration - Automatic Termination when completed Programmable Voltage Set point and Duration - Automatic Termination when completed
Battery Temperature Compensation Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell
Voltage Step-Down Capability Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input
Programmable Auxiliary Control Output 12 VDC output signal which can be programmed for different control applications
(Maximum of 0.2 amps DC)
12 VDC output signal which can be programmed for different control applications
(Maximum of 0.2 amps DC)
Status Display 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total
Remote Display and Controller Optional Mate or Mate2 with RS232 Serial Communications Port Optional Mate or Mate2 with RS232 Serial Communications Port
Network Cabling Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)
Data Logging Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production
Hydro Turbine Applications Consult factory for approved Turbines Consult factory for approved Turbines
Positive Ground Applications Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications)
Operating Temperature Range Minimum -40° to maximum 60° C
(Power capacity of the controller is automatically derated when operated above 40° C)
Minimum -40° to maximum 60° C
(Power capacity of the controller is automatically derated when operated above 40° C)
Environmental Rating Indoor Type 1 Indoor Type 1
Conduit Knockouts One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom
Warranty Standard 5 year / Available 10 Year Standard 5 year / Available 10 Year
Weight - Unit 12.20 lbs. (5.56 kg) 11.65 lbs. (5.3 kg)
         - Shipping 15.75 lbs. (7.10 kg) 14.55 lbs. (6.4 kg)
Dimensions - Unit 16.25" x 5.75" x 4" (41.3 x 14 x 10 cm) -
(H x W x D)
13.5 x 5.75 x 4" (40 x 14 x 10 cm)
         - Shipping 21" x 10.5" x 9.75" (53 x 27 x 25 cm) 18 x 11 x 8" (46 x 30 x 20 cm)
Options Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2 Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2
Menu Languages English & Spanish English & Spanish
blackout power

Magnum MMS1012 E-Panel Power System Documents & Manuals

Product Documents & Manuals

 
magnum Magnum Energy MMS1012 Data Manual
 
batteries Batteries
 
12v MidNite Solar Classic 150 Data Manual
 
12v MidNite Solar Classic 150 Charge Controller Operators Manual
 

Magnum MMS1012 E-Panel System Pre-wired Power Center 120 AC Pure Sine Wave Power

Magnum MMS1012 E-Panel System Power Centers is solid-state electronic device that, when sized properly, can be used in nearly every solar and wind energy system that uses batteries. The Power Centers Blue Pacific Solar sells employ the latest in power electronics to regulate the battery charge by controlling the charging voltage and current from a solar panel array. Power Centers regulate the charge of the battery, but also prevent the battery from being over discharged which can damage the battery bank.

Off-grid or grid tied with battery backup, here is how the Magnum MMS1012 E-Panel System basically works. For a grid tied battery backup, grid power comes into the Magnum MMS1012 E-Panel Power System. If the backup batteries are fully charged, the power is then passed to the critical load or backup load subpanel inside the home. The Outback FlexPower power system is monitoring the sine wave of the grid, amps and volts. When the Magnum MMS1012 E-Panel Power System detects changes outside the default parameters, it immediately begins to draw power from the backup battery system and pushes it to the critical load subpanel.

If you have solar panel system connected to the Magnum MMS1012 E-Panel Power System, the power center will use the electricity produced by your solar panels to charge the batteries making Magnum MMS1012 E-Panel Power System a great choice for home backup and off-grid systems.

Magnum MMS1012 E-Panel System Power Center uses multiple stages of control to regulate different voltage and current levels. The voltage and current of a battery varies over the different stages of battery charge. Though the amount can vary, the bulk charge usually is approximately 80%, the absorption charge is 10% with the float charge representing the balance of the battery charging process.

The bulk charging stage of the Magnum MMS1012 E-Panel System Power Center process is the first stage to used to bring the battery depth of discharge (DOD) back to 100%. The bulk charge stage happens first in in the morning after the batteries DOD has drained down since sunset the previous day. The bulk charging stage pushes as many amps into the battery bank as possible from the solar panels and gets the voltage up in the process. The effect of a Power Center is not unlike trying to fill a glass of water from a faucet. You first turn the faucet on full while the glass if filling, then slowly taper off the pressure until the glass is full. When the battery bank reaches a predetermined level known as the bulk voltage set-point, the charge is then substantially slowed. Because the bulk voltage set point is determined by the type of battery you are using, many Power Centers have to be pre-set to the type of battery which will dictate the rate of charge.

The second state of charge the Magnum MMS1012 E-Panel System Power Center employs is the absorption stage. After a battery system has been brought up to the bulk voltage set point, the Power Center slows down the charge rate because the battery bank cannot accept the same rapid charging pace without overheating and damaging the battery bank. At the absorption stage a battery bank is only about 80% full. The absorption charge is the function level in the process that tops off the battery bank. During the absorption stage, the Power Center holds the battery volts constant and reduces the amount of current sent into the battery. When the absorption stage is complete, the battery bank is fully charges.

The final step the Magnum MMS1012 E-Panel System Power Center performs is the float charge. Typically a Power Center enters into a float charge state when the other charge levels of the battery bank has been achieved. When the number of peak sun hours is limited, a solar Power Center may not be able to get the battery bank back to the float stage before the next cycle begins.

Each Magnum MMS1012 E-Panel Power System comes pre-wired with inverter, charge controller all mounted on a rack ready to power up. You simply have to finish connecting into your battery bank and wire to your breaker box or subpanel. Simple, easy, fast.

magnum midnite e-panel IMPORTANT SAFETY INSTRUCTIONS: Magnum MMS1012 E-Panel System Power Center. (OK, here is the scary legal disclaimer.) It is the responsibility of the purchaser to ensure that all products are installed and operated in accordance with local and national building codes as specific by the NEC (National Electric Code), UBC (Uniform Building Code) or IBC (International Building Code) and local utility company policy. This product is designed for indoor or protected compartment installations. DO NOT expose the Magnum Panel System to rain, snow, moisture or liquids of any type. Use insulated tools to reduce the chance of electrical shock or accidental short circuits. Remove all jewelry such as rings, watches, bracelets, etc when installing the Magnum Panel System Power Center or any other electronic gear. Always disconnect the batteries or energy source prior to installation or performing maintenance on the Magnum Panel System Power Center inverter. Live power may be present at more than one point since an inverter utilizes both batteries and AC electricity. Turning off the Magnum Panel System Power Center may not reduce that risk. Always verify proper wiring prior to starting the inverter. Do not operate the Magnum MMS1012 E-Panel System Power Center if it has been damaged. Always read and follow the manufactures installation and operating instructions for the Power Center prior to installation and operation.