Pre-Wired Power Center

power system

web solarStore

 

 

  • Blue Pacific Solar Products, Inc. BBB Business Review

 

Magnum MNEMS4024PAECL150 Power Center

canadian solar
      off grid
    • Magnum E-Panel
    • This Magnum power center with Midnite Solar Classic 150 charge controller is a fabulous AC pre-wired power system. Mechanically and electrically engineered, every component of this system has been specially selected to assure the highest performance with this safe simple-to-install unit. This off-grid kit is ideal for applications with smaller power requirements such as off-grid cabins, and limited back-up power systems. Utilizing a compact design and an easy-to-install mounting bracket, the fully pre-wired and tested Magnum / MidNite e-panel power center is designed for a quick installation, saving both time and money with just a few household tools. The pre-wired power center with MidNite Solar Classic 150 maximum power point tracking offers an efficient, safe, multi-stage recharging process that prolongs battery life and assures peak performance from your solar array.
    • Only: Buy Now
  • Product Details:
  • Specifications:
  • Videos:
  • Documents:

MidNite / Magnum MNEMS4024PAECL150 Power System

Model Part Number Output Watts Breaker Voltage DC/AC Type Shipping Weight
MNEMS4024PAECL150 03304303 4000 30A 24VDC / 120/240VAC Off-Grid / On Grid 190 lbs

 

magnum

 

The Magnum MS4024PAE is designed for use with 24V battery system and no more than 4,000 watts continous power demand. This MidNite Solar; Magnum Energy power center accommodates all of the essential protective devices in the smallest possible space. This is an affordable simple application satisfying the hungry power requirements such as cabins, chalets, remote communication sites and small back-up power systems. Utilizing an extremely compact design and an easy-to-install mounting bracket, the fully pre-wired and tested Magnum power center is designed for a quick installation. Choose either roof, ground or pole mount rack which will save you both time and money. As with all Blue Pacific Solar's kits, our technical sales staff is standing by to provide support that is as close as your telephone.

The MS Series is a pure sinewave inverter providing a cost effective solution for those with smaller power needs in mobile applications. Versatile, easy-to-use, and lightweight, the MS Series provides a reliable base for your energy system.

The MidNite Classic 150 charge controller is the most versatile on the market today. In 2011 NEC required that charge controllers be equipped with arc fault protection. the Classic is the first MPPT controller that has standard arc fault protection making the Classic the safest available of our customers as well as fire departments. The Classic MPPT charge controller is the controller all the other equipment manufactures wanna be. With a amp rating from 63 to 96 amps, why would you look elsewhere?

Available on to use with 24V battery system, the MS Series inverters is a small, powerful, easy-to-use and ETL listed to the stringent requirements of UL 1741 and CSA C22.2 No. 107.1-01 for Renewable Energy installations. Magnum Energy / MidNite Solar e-panels are a superior choice when you need a fully integrated, pure sinewave, reliable 120/240V power system. Power Center Warranty 5 Years.

solar kits 

What's On The Truck

  • 1 - Midnite, Magnum MNEMS4024PAECL150, Pre-wired power center with Controller
  • INCLUDES:
  • Midnite CL150 Classic 150 MPPT Charge Controller
  • MNE250STM-L -240 E-Panel white steel E-Panel
  • MS4024-AE 4000 watt inverter/chargerpower system
  • ME-RC50 remote display
  • ME-BMK-NS
  • 1 MNEPV2 breaker for BMK
  • 2 MNEDC panel mount breakers (for the Classic)
  • 250 amp Battery Main Breaker
  • DC-GFP - built into the Classic
  • Arc Fault Detector - built into the Classic
  • 3 MNSPD (Surge Protection Devices)
  • 1 MidNite BTS, 1 Magnum BTS
  • 1 - Line Drawing

magnum ship MidNite Magnum power systems are built to order. Allow 15 business days to ship. (Subject to Seasonal Increases)

 

Electrical Specifications, 120/240 Vac / 60 Hz ± 0.001%
Product Name MNEMS4024PAECL150
Off-Grid / On-Grid Yes
Anti-Islanding Protection UL1741-2005/ IEEE1547
Output Waveform Pure Sine Wave
Battery Voltage (Nominal) 24 Vdc
Recommended Minimum Battery Capacity 200 Amp-hours
Maximum Solar Array Wattage 4000 W/STC
Certifications Listed by ETL for US and Canada
Warranty 5-year Warranty Standard

magnum shipMagnum inverters are on-grid but will not export excess power. Inverters can use either the utility grid or fossil fuel generator to recharge a battery bank in conjunction with the MidNite Classic 150 charge controller.

magnum shipModified sine wave inverters may not run: Laser printers, photocopiers, and anything with an electrical component called a thyristor; Anything with a silicon-controlled rectifier (SCR) like those used in some washing machine controls; Some laptop computers (Apple Products can be particularly fussy about their energy source); Some fluorescent lights; Some new furnaces and pellet heaters with microprocessor controls; Digital clocks with radios; Appliances having speed controls; Medical equipment should not be power with modified sine wave inverters. Because the total harmonic distortion is higher in modified sine wave inverters, you may hear a buzzing from your stereo system and you might see lines on your TV.

 

trojan battery manual

 

Optional Deep Cycle Battery Choices; Trojan / UPG / Rolls

stand alone kits

Choose the off-grid battery option that best fits your needs. The size of the battery bank you choose depends on the amount of power you require (Watts), the amount of time each day you expect to run your appliances, equipment and lights, and your location or available sunlight. As a rule-of-thumb, when considering batteries off-grid, use 3 days of autonomy (No Sun) as a minimum and 50% depth of discharge for your battery bank.

MFG
Model
Item #   Volt Amp Hour (20Hr Rate) Data WTY 48V Battery Bank Watt Hours Price per Watt Price EA  
Trojan
T-105RE
Flooded Lead Acid
BP4001937 agm battery 6V 225 Ah battery cell 2 YRbattery warranty 8 / T105RE
= 10,800 Wh
$0.11
Qty
Trojan
L16RE-A
Flooded Lead Acid
BP4001967 agm battery 6V 325 Ah battery cell 5 YRtrojan warranty 8 L16RE-A
= 15,600 Wh
$0.15
Qty
UPG
UB-GC2
Sealed AGM
BP9996646 agm battery 6V 200 Ah battery cell 1 YRupg warranty 8 / UB-GC
= 9,600 Wh
$0.21
Qty
Rolls
S6-460
Sealed AGM
BP9946055 surrett S-460AGM 6V 415 Ah agm battery 5 YRserette warranty 8 / S6-460
= 19,200 Wh
$0.21
Qty
Rolls
S-1380
Flooded Lead Acid
BP4002113 surrett 530ah 2V 1050 Ah battery cell 7 YRrolls warranty 24 / S6-460
= 50,400 Wh
$0.16
Qty

 

Battery Cable Pairs (RED/Black) Length Color Part # Price
 2/0 - Battery Cables 12"  1 Red/1 Blackcables BP9850022
Qty
 2/0 - Battery Cables 18"  1 Red/1 Blackcables BP9850012
Qty

 

Optional Roof or Ground Rack Part # Price  
1 Set Basic IronRidge Ground Racking Option D (6 Rack Sets Required for 6 Solar Panels)ironridge solar racks  BP6932304solar ground rack
Qty
1 Set Basic IronRidge Roof Mount Racking Option D (6 Rack Sets Required for 6 Solar Panels) ironridge solar racks
 BP6932304solar roof rack
Qty

 

Inverter Options Description Part # Price  
ME-AGS-N Automatic Generator Start WORKS WITH;
ME Series, MM Series, MMS Series, MS Series, MS-PAE Series, RD Seriesmppt
BP2911442solar charger
Qty

 

magnum midnite

 

**Freight Shipping is Dock to Dock

magnum inverters magnum power center

In circumstances where we have to ship by freight, free or otherwise, that means dock to commercial dock (not residential) to any of the lower 48 states. If the customer does not specify a local commercial dock that is available, we will ship to the nearest terminal where the shipment will be held for will call pick up by the customer. If you choose to have your order shipped to your residence, most orders require special handling for unloading and the pallet has to be transferred to a truck with a lift gate. In most cases, truck freight companies do NOT require their drivers to unload shipments. An additional "Residential" as well as a "Lift Gate" special handling fee will apply if the driver unloads the merchandise to the curb at your residence. The special handling fee is $89.00 and is available at checkout. If you have selected this add on service, the shipping carrier will call and schedule delivery of your solar kit, (provided the weight and dimensions of the product fits the criteria for lift gate service). You can avoid the residential and lift gate fees by arranging a "Will Call" pickup at the closest freight company terminal. In that case, you will need a pickup truck, a copy of the bill of laden, and a photo ID. When you arrive at the freight company terminal, the freight company will load your order into the bed of the truck with their forklift. The most common pallet size = 65" X 44" (Height depends on Product). Be sure and check for hidden damage.

Inverter Specifications

Magnum Energy MS4024PAE Inverter

Input battery voltage range 36.0 - 68.0 VDC
Nominal AC output voltage 120/240 VAC split phase (± 5%)
Output frequency and accuracy 60 Hz ± 0.1 %
1 msec surge current (amps AC) Line-Neutral: 120, Line-Line: 70
5 sec surge power (real watts) 5800
30 sec surge power (real watts) 5200
5 min surge power (real watts) 4800
30 min surge power (real watts) 4500
Continuous power output at 25° C 4000 VA (L-L)
Maximum continuous input current 266 A
Inverter efficiency (peak) 93%
No load (120 VAC output, typical) 27 watts
Waveform Pure Sine Wave
 

Charger Specifications

Charger Continuous output at 25° C 105 ADC
Input current at rated output (AC amps) 15 AAC per leg at 120/240 VAC split phase
Power factor > 0.95
 

General Features and Capabilities

Transfer relay capability 2 legs at 30A per leg transfer standard on all models
Five stage charging capability Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™
Remote available (optional) Yes, MM-RC or ME-RC
Over current protection Yes, with two overlapping circuits
Conformal coating on PCB’s for corrosion protection Yes
Listings ETL Listed to ANSI / UL1741, 1 edition, and CSA STD C22.2 No.107.1-01
Warranty Two years
 

Environmental Specifications

Operating temperature -20° C to +60° C (-4° F to 140° F)
Non-operating temperature -40° C to +70° C (-40° F to 158° F)
 

Physical Specifications

Dimensions (L x W x H) 13.75” x 12.65” x 8.0”
Mounting Shelf, wall (no vents on bottom), MP or MMP panels
Weight 55 Lbs
Shipping Weight 60 Lbs
Max operating altitude 15,000’
 

 

MidNite Solar Classic Charge Controllers
Classic 150 Classic 200 Classic 250 Classic 250KS
Operating Volts In 150VDC 200VDC 250VDC 250VDC
*Max Hyper VOC 150+ battery 200+ battery 250+ battery 250+ battery
Nominal Battery Volts 12-72 12-72 12-72 12-120
**Absolute Current Output at 25° C

93a@12v battery

94a @ 24v battery

83a @ 48v battery

74a @ 12v battery

70a @ 24v battery

65a @ 48v battery

60a @ 12v battery

62a @ 24v battery

55a @ 48v battery

40a @ 120v battery
De-Rate Current @ 40° C 80 amperes 60 amperes 52 amperes 33 amperes
Environment -40° C to 40° C
Classic Dimensions 14.87” x 5.95” x 4.00” (378 mm x 151 mm x 102 mm)
Boxed Dimensions 19.00” x 8.50” x 5.70” (378 mm x 151 mm x 102 mm)
Shipping Weight 11.5 lb (4.9 kg)

NOTE: Current output ratings were measured with 75% of the PV array’s VOC (Open Circuit Voltage)
*NOTE: Calculated by adding battery voltage to the maximum input operating voltage (48V battery max)
**NOTE: Measurement Accuracies: +-0.12v, offset calibration adjustment may be necessary

 

Magnum MNEMS4024PAECL150 MidNite e-panel Pre-wired Power System

Magnum MNEMS4024PAECL150 MidNite e-panel pre-wired systems solid-state electronic devices that, when sized properly, can be used in nearly every solar and system that uses batteries. The Power Centers Blue Pacific Solar sells employ the latest in power electronics to regulate the battery charge by controlling the charging voltage and current from a solar panel array. Power centers with inverter chargers and charge controllers regulate the charge of the battery, but also prevent the battery from being over discharged which can damage the battery bank.

midnite classic IMPORTANT SAFETY INSTRUCTIONS: (OK, here is the scary legal disclaimer.) It is the responsibility of the purchaser to ensure that all products are installed and operated in accordance with local and national building codes as specific by the NEC (National Electric Code), UBC (Uniform Building Code) or IBC (International Building Code) and local utility company policy. This product is designed for indoor or protected compartment installations. DO NOT expose the power center to rain, snow, moisture or liquids of any type. Use insulated tools to reduce the chance of electrical shock or accidental short circuits. Remove all jewelry such as rings, watches, bracelets, etc. when installing the MidNite Magnum Power Center or any other electronic gear. Always disconnect the batteries or energy source prior to installation or performing maintenance on the MidNite Magnum Power Center inverter. Live power may be present at more than one point since an inverter utilizes both batteries and AC electricity. Always verify proper wiring prior to starting the inverter. Do not operate the system if it has been damaged. Always read and follow the manufactures installation and operating instructions for the Magnum MNEMS4024PAECL150 power system prior to installation and operation.