Magnum MS4024 4000 Watts 24 Volts Pure Sine Wave Inverter
- #BP2940241 Magnum MS4024 Inverter
- More Watts, More Power than its little brother, the Magnum Energy MS4024 series inverter / battery charger is easy-to-use, and cost effective pure
sine wave inverter. Pure sine wave: Power your T.V.s, stereos, plasma screens, and other sensitive electronics without worry.
Power Factor Corrected (PFC) Charger: the Magnum MS2012 PFC charger is built into all of Magnum inverter chargers. Magnum MS2012
uses less energy from a generator than a standard charger using 25-30% less AC current than standard chargers.
- Only: Buy Now
- Product Details:
- Specifications:
- Videos:
- Documents:
Magnum MS4024 Pure Sine Wave Marine, RV & Emergency Backup AC Inverter
| Model | Part Number | Watts | Input Voltage | Output Voltage | Type | Amps Continuous Charge |
| Magnum MS4024 Inverter | BP2940241 | 4,000 | 24 VDC | 120 VAC | Pure Sinewave / Off-Grid | 105 ACD (25*C) |
Designed specifically for the most demanding off-grid applications, the Magnum MS4024 inverter / battery charger is an affordable AC power source for Marine, RV or Emergency backup AC power. The Magnum MS4024 is powerful, easy-to-use, and best of all, cost effective. Install the Magnum MS4024 in four easy steps: simply connect the inverter's output to your distribution circuits or electrical panel, connect your shore power cable (AC) or RV cable to the inverter's easy-to-reach terminal block, connect the batteries, and switch on the power.
Safe and reliable: The MS2000, MS2012, MS2812, and MS4024 are ETL Listed to the stringent requirements of UL/cUL 458 for mobile use and the MS2012, MS2812, and MS4024 are ETL Listed UL 1741 and CSA C22.2 #107.1-01 for renewable energy installations. All models also meet KKK-A-1822E standards for emergency vehicle use. The Magnum MS4024 is ETL listed to the stringent requirements of UL/cUL 458 for mobile use and UL 1741 for off grid installations.
What's In The Box
- 1 - Magnum Energy MS4024 Pure Sine Wave Inverter
Optional Accessories
![]() |
Part # | Price | |
| 1 - ME-RC-50 Magnum Energy Remote Control Monitor |
BP2910000 |
||
| 2 Trina 180 Watt Solar Modules Silver (Equal or Better); 1 Morningstar TriStar TS-45, MPPT; 1 IronRidge XRS Ground Rack Kit for 2 Panels |
BP9200360![]() |
||
| Conduit Box (white) for AC and DC Wiring to Conduit for MS, ME RD Magnum Inverters |
BP6932304 |
||
| ME-BMK Battery Monitor Kit with Shunt |
BP9915942 |
||
| ME-AGS Network - Magnum Automatic Generator Start used with ME-RC 50 |
BP2911442 |
||
| ME-AGS-S Stand Alone - Magnum Energy ME AGS-S Generator Start Module, Stand Alone |
BP2921442 |
||
| ME-MR Magnum Energy Inverter Remote Control / NOTE: The Magnum ME-MR remote unit is a basic remote control unit, which only includes minimal settings in the setup menu. Carefully evaluate your needs when considering this remote over the more comprehensive ME- RC remote control unit. |
BP2912542 |
||
| ME-MW-W MagWeb - Wireless Monitoring Kit /
The ME-MW-W MagWeb - Wireless Monitoring Kit is a powerful and cost effective tool for remotely monitoring your Magnum Energy’s inverter and accessories. |
BP2944002![]() |
| Compatible Disconnects / Magnum Energy MS4024 Inverter | Part # | Price | |
| Midnite Solar MNE175STM-L Magnum E-Panel with 175A/125VDC Inverter Breaker |
BP8912510![]() |
Inverter Specifications |
|
Magnum Energy MS4024 Inverter |
|
| Input battery voltage range | 18 - 34 VDC |
| Nominal AC output voltage | 120 Volts AC |
| Output frequency and accuracy | 60 Hz ± 0.1 % |
| 1 msec surge current (amps AC) | 120 |
| 5 sec surge power (real watts) | 5800 |
| 30 sec surge power (real watts) | 5400 |
| 5 min surge power (real watts) | 4900 |
| 30 min surge power (real watts) | 4500 |
| Continuous power output at 25° C | 4000 VA |
| Maximum continuous input current | 266 ADC |
| Inverter efficiency (peak) | 87% |
| No load (120 VAC output, typical) | 7 watts |
| Waveform | Pure Sine Wave |
Charger Specifications |
|
| Charger Continuous output at 25° C | 105 ADC |
| Input current at rated output (AC amps) | 29 |
| Power factor | > 0.95 |
General Features and Capabilities |
|
| Transfer relay capability | MS2000: 30 A single input MS2012, MS2812, MS4024: 2 legs at 30 A for 120 V/30 A or 240 V/60 A service |
| Five stage charging capability | Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™ |
| Remote available (optional) | Yes, MM-RC or ME-RC |
| Over current protection | Yes, with two overlapping circuits |
| Dual AC branch rated output breakers | Optional on the MS2000 and MS2012 - AC breakers in 15 or 20 amp ratings |
| Listings | ETL Listed to UL/cUL 458, UL 1741, CSA C22.2 #107.1-01, meets KKK-A-1822E standard |
| Warranty | Three years |
Environmental Specifications |
|
| Operating temperature | -20° C to +60° C (-4° F to 140° F) |
| Non-operating temperature | -40° C to +70° C (-40° F to 158° F) |
Physical Specifications |
|
| Dimensions (L x W x H) | 13.75” x 12.65” x 8.0” |
| Mounting | Shelf (top or bottom up) or bulkhead (vents up) |
| Weight | 55 Lbs |
| Shipping Weight | 60 Lbs |
| Max operating altitude | 15,000’ |
Magnum Energy Inverter Documents & Manuals
|
|
|
|
|
|
Magnum MS4024 Pure Sine Wave Inverter Marine / RV / Emergency Battery Backup 24 volts 4000 Watts
Magnum MS4024 inverters are the brains of your new solar system. A Magnum MS4024 inverter will change the direct current (DC) power produced by the solar panels, or stored energy in batteries, and convert it into alternating current (AC) electricity that home, RV or Marine owners can use to power T.V.s, stereos, plasma screens, and other sensitive electronics without the distortion or electrical lines you sometimes get with modified sine wave inverters.
When your Magnum MS4024 inverter is operating in inverter mode, DC electricity from your batteries is changed into pure sine wave AC power that works with most small electronics and mobile applications. When you batteries are charged 100%, the Magnum Energy MS4024 inverter switches over to standby mode. The Magnum MS4024 operates as a battery charger to convert incoming AC power into DC power to recharge your batteries while continuing to pass through incoming AC power directly to the inverters output ports.
Magnum Energy MS4024 inverters can be used for a variety of purposes from emergency backup power centers to mobile applications such as an RV, truck or boat. In these applications the Magnum MS4024 inverter provides power to the AC outlets using energy stored in the batteries of your RV, truck or marine vessel. The Magnum Energy MS4024 can power a wide range of household, RV or marine appliances. As with any appliance using batteries for power, there is a certain length of time called "run time" that your batteries will provide electricity. Actual run time is dependent of several variables including the size and type of appliance, the type of batteries installed as well as the age and battery's capacity. Other environmental factors can affect the amount of power your Magnum MS4024 can provide such as your battery's state of discharge (or charge) and the temperature where the batteries are stored.
To evaluate your power requirements look at the name plate of the largest electronic appliance you want to run then look at the watt and surge rating of the Magnum MS4024. Your inverters consistent power capacity and surge capacity should be allow a 25% calculation factor when measured against the highest energy demand of your appliance.
IMPORTANT SAFETY INSTRUCTIONS: Magnum MS4024.
(OK, here is the scary legal disclaimer.) It is the responsibility of the purchaser to ensure that all products are installed and operated
in accordance with local and national building codes as specific by the NEC (National Electric Code), UBC (Uniform Building Code) or IBC
(International Building Code) and local utility company policy. This product is designed for indoor or protected compartment
installations.
DO NOT expose the MS4024 to rain, snow, moisture or liquids of any type. Use insulated tools to reduce the chance of electrical shock or
accidental short circuits. Remove all jewelry such as rings, watches, bracelets, etc when installing the Magnum MS4024 inverter or any
other electronic gear. Always disconnect the batteries or energy source prior to installation or performing maintenance on the Magnum MS4024
inverter. Live power may be present at more than one point since an inverter utilizes both batteries and AC electricity. Turning off the
Magnum MS4024 inverter may not reduce that risk. Always verify proper wiring prior to starting the inverter. Do not operate the Magnum MS4024
inverter if it has been damaged. Always read and follow the manufactures installation and operating instructions for the Magnum Energy MS4024 inverter prior
to installation and operation.